A laboratory information system should make the current state of an order and specimen understandable without reconstructing the story from disconnected notes. It should show what was requested, what was received, what happened, who was responsible, which exceptions occurred, and what result was authorized for release.

01

Define the laboratory boundary

Start with disciplines, locations, collection points, referral arrangements, users, devices, test volumes, service hours, and result consumers. Clarify whether the project is an LIS for clinical diagnostic workflows, a broader LIMS for laboratory operations, or a defined combination. Labels vary, so requirements must carry the meaning.

List the systems that create orders, register patients, receive results, manage billing, supply reference data, or support reporting. Identify manual steps that remain in scope because the software must still represent their status and outcome.

02

Map the order-to-result workflow

Describe order entry, patient matching, preparation, collection, labeling, transport, receipt, accessioning, routing, processing, review, verification, release, amendment, and notification. Include repeat testing, add-on tests, cancellations, insufficient samples, identification problems, delayed specimens, referred tests, and critical results.

Every transition needs an entry condition and accountable role. A status should represent a defined operational state, not simply the last screen a user opened.

Traceability test

For any released result, the organization should be able to identify the order, patient or subject, specimen, processing path, responsible users, verification state, amendments, and release destination.

03

Design identifiers and specimen traceability

Define patient or subject identifiers, order identifiers, accession numbers, specimen identifiers, container relationships, aliquots, pooled samples where relevant, and labels. Determine where identifiers are generated and how duplicates or mismatches are resolved.

Traceability may require timestamps, users, work areas, storage locations, custody or status events, transport conditions, rejection reasons, and final disposition. The CDC’s laboratory competency guidance describes electronic tracking and complete documentation as part of laboratory quality and chain-of-custody capability. See the official CDC laboratory competency guidance.

04

Separate result entry, review, verification, and release

These states may be performed by different roles under different rules. Define who can enter, modify, verify, authorize, release, amend, or cancel a result. Establish the handling of units, reference intervals, flags, comments, calculations, attachments, corrections, and retained original values.

Critical or significant results require an agreed communication workflow. The system may support identification, notification, acknowledgement, escalation, and evidence, but policy and responsible staff remain essential.

05

Specify analyzer and clinical-system interfaces

For each analyzer, identify the device, protocol, unidirectional or bidirectional exchange, worklist behavior, result format, units, flags, corrections, validation rules, connection boundary, vendor responsibilities, and error handling. Interface testing should use real supported message patterns and known exception cases.

For EMR or order-entry integration, define patient matching, order codes, specimens, priorities, statuses, cancellations, results, amendments, acknowledgements, failed-message queues, retries, and reconciliation. A message that leaves one system has not succeeded until the receiving workflow can account for it.

06

Support quality without overstating automation

Requirements may include worklists, pending items, turnaround review, rejected specimens, corrected results, quality-control records, maintenance links, referral tracking, and management reports. Define the responsible interpretation and the source of each rule or reference range.

Audit history should preserve meaningful changes without making routine review unusable. Reports should expose exceptions and trends that lead to action, not merely export all available fields.

07

Laboratory system evaluation checklist

  1. Can each order, specimen, container, result, and amendment be uniquely identified?
  2. Do statuses have agreed operational definitions and responsible roles?
  3. How are mismatches, rejected specimens, repeats, add-ons, and referrals handled?
  4. Who can enter, verify, release, amend, and cancel results?
  5. How are critical results communicated and acknowledged?
  6. How are analyzer and EMR interface failures detected and reconciled?
  7. Which reports support pending work, quality review, and operational oversight?
  8. How will the laboratory continue and reconcile work during downtime?

QUICK ANSWERS

Laboratory information system FAQ

What is the difference between LIS and LIMS?

Usage varies. LIS often refers to clinical diagnostic laboratory workflows, while LIMS may refer to broader sample and laboratory operations. Define the required workflow, data, controls, and interfaces instead of selecting by label.

Can an LIS connect to analyzers?

It can when the device, supported protocol, data direction, worklist and result behavior, validation, security boundary, testing, and support ownership are confirmed.

Can results be sent to an EMR automatically?

Yes, but release rules, patient and order matching, structure, acknowledgements, failures, amendments, and reconciliation must be designed and tested.

RELATED SOLUTION

Laboratory solutions

Review PraxisOne scope for order management, samples, worklists, verification, result release, and clinical reporting workflows.